This article explains how to add a calibration to an asset, using spray treatment application equipment as an example. It covers both calibration types: volume and speed.
Adding a calibration
- Open the asset and go to the calibration table.
- Click Add Calibration.
- Select the calibration type: Volume or Speed.
Volume calibration
Calibration details
Fill in the following fields:
- Calibration date
- Number of nozzles
- Nozzle spacing. The boom length is calculated automatically.
- Pass length
- Output tolerance
- Spray pressure and its unit
- Nozzle type
You can also add more nozzle details:
- Nozzle model
- Nozzle trade name
- Nozzle tip size
- Nozzle tip color
- Nozzles per row
- Nozzle filter mesh
Catch output
- Select the form type: Nozzles or Applicator output.
- Select the volume unit, for example, liters.
- Enter the catchment time, for example, 60 seconds.
- Record the volume for each emitter.
The drip line delivery and the average nozzle output are calculated automatically.
Results
At the bottom of the window, you'll see:
- Expected output range
- Average nozzle/emitter output
- Total output
Finally, select the calibration rate unit (for example, liters per hectare), enter the calibrated rate, and click Done.
Speed calibration
Calibration details
Fill in the following fields:
- Calibration date
- Nozzles per boom, if you need to change it
- Nozzle spacing. The boom length is calculated automatically.
- Number of calibration passes. Click the plus sign (+) to add more.
- Pass length
- Output tolerance
- Spray pressure and its unit
- Nozzle details: type, model, trade name, tip size, tip color, nozzles per row, and filter mesh
Catch output
- As in the volume calibration, select the form type: Nozzles/emitter output or Applicator output.
- Enter the catch time, for example, 60 seconds.
- Record the volume of each nozzle emitter.
The boom drip line delivery and the average nozzle emitter output are calculated automatically.
Speed calibration
At the bottom of the window, the speed calibration section records time and distance to calculate the average ground speed. Enter the pass time for each pass, for example, 120 seconds.
Results
Based on this information, the following values are calculated automatically:
- Average pass time
- Ground speed
- Calibrated rate
- Expected output range
- Average nozzle emitter output
- Calibrated volume applied per pass
- Total output
💡 Tip: Hover over the info icon next to a calculated field, such as the calibrated volume applied per pass, to see the formula used.